Experience unmatched comfort and efficiency with the Pioneer® WYF-25 Hyperformance™ series of ductless mini split heat pumps. These revolutionary systems redefine year-round comfort, providing exceptional heating and cooling performance even in extreme weather conditions as low as -22°F.
Summary
- Ultra Low Ambient Hyperformance™ Ductless Mini Split Hyper Heat Pump System
-
Cooling capacity: 12,000 BTU/H (1 Ton) with 23.5 SEER2 / 12.7 EER2 efficiency
-
Heating capacity: 12,000 BTU/H (1 Ton) with 9.5 HSPF2 / 3.74 COP efficiency
-
Voltage: 208/230V, 60Hz, 1Ph
- High Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Hyper Heat Unit (Continues heating in -22°F weather)
- Wireless Internet Access Included (Via Free Smartphone App)
Key Features
Energy-Star Certified Efficiency
Save on utility bills with Energy-Star certification and qualify for rebates nationwide.
Heavy Duty Heating in -22°F
Engineered to keep your space warm in extreme cold with up to 88% capacity retention.
Dual-Swing 3D Louver
Ensure optimal airflow distribution with automatic dual-directional louvers.
Dependably Durable Design
Built to withstand harsh climates with galvanized steel panels and anti-corrosion coil.
Wi-Fi Controllable
Control your system remotely with the free app, set custom schedules, and integrate with smart home setups.
High-Density Air Particle Filtration
Improve air quality with ultrafine and supplemental filters, eliminating pollutants and odors.
What's Included
- Indoor Unit
- Outdoor Unit
- Wireless Remote Control (with wall holder and batteries)
- Internet Control Module
- Copper Lines*
- Signal Cable Between Units*
- Drain for Indoor/Outdoor*
- Wall Passage Sleeve*
- Putty for Wall Hole*
- Leak Guard Sealer
- Wrapping Tape
- Installation Manual
- User’s Manual
- (*If ordered with an installation kit)
PRODUCT SPECIFICATIONS
Condenser Dimensions |
31 7/8" W x 11" D x 23" H |
Condenser Weight |
72.6 lbs |
Air Handler Dimensions |
33 1/2" W x 8 1/8" D x 10 5/8" H |
Air Handler Weight |
18.7 lbs |
SEER2 |
23.5 BTU/W.h |
EER2 |
12.7 BTU/W.h |
COP 47 |
3.74 / 1.98 W/W |
HSPF2 |
11 / 9.5 BTU/W.h |
Cooling Capacity |
12,000BTU (3,000BTU - 14,000BTU) |
Heating Capacity |
12,000BTU (3,000BTU - 16,000BTU) |
Cooling Rated Current |
4.3A / 940W |
Heating Rated Current |
4.3A / 940W |
Voltage |
Requires a minimum of 208-230V, 60Hz, 1Ph (please check your home meets this electrical requirement prior to purchase) |
Phase |
1 |
Cycle |
60 Hz |
Max Coverage Area |
200-550 sq. ft. |
Zone Capacity |
1 |
Refrigerant Type |
R-410A |
Indoor Decibel Rating |
39 / 32 / 29 (Hi/Med/Lo) |
Indoor Decibel Rating |
53 (High) |
Inverter |
Yes |
Line Set Length |
Choose between 10ft., 16ft., 25ft., 33ft., and 50ft. line set. |
Maximum Line Set Length |
20m / 65ft |
Liquid Pipe Diameter |
1/4” |
Gas Pipe Diameter |
3/8” |
Wifi Compatibility |
Yes |
App Compatibility |
Yes |
Compatible with |
IOS Android
|
Control |
Handheld Remote Controller (Included/Default), or Wired Controller (Optional/Sold Separately) |
Certifications |
Energy Star AHRI
|
Warranty |
5 years Warranty for Parts 5 years for Compressor |
INSTALLATION & GUIDES
What Our Experts Think
-
Powerful & Efficient – 12,000 BTU capacity with Energy Star certification for lower energy costs.
-
Year-Round Comfort – Hyper Heat technology ensures reliable heating even in extreme cold.
-
Easy Installation – Comes with indoor & outdoor units, remote, and installation accessories.
-
Smart Control – Compatible with Wi-Fi thermostats for convenient remote operation.
-
Quiet & Compact – Ultra-quiet operation, perfect for bedrooms, offices, and living spaces.
-
Eco-Friendly – Uses R-32 refrigerant, reducing environmental impact.
Q&A
Q: What is the Pioneer Hyperformance 12K BTU Ductless Mini Split Hyper Heat Pump?
A: The Pioneer Hyperformance 12K BTU Ductless Mini Split is a high-efficiency heating and cooling system designed for year-round comfort. With hyper heat technology, it delivers reliable heating even in extreme cold temperatures, making it ideal for homes in colder climates.
Q: What makes this system "Hyperformance"?
A: The Hyperformance series is designed for exceptional heating performance even in sub-zero temperatures. Unlike standard heat pumps, this unit maintains efficiency at lower outdoor temperatures, providing consistent warmth without relying on auxiliary heating.
Q: Is this unit Energy Star certified?
A: Yes, the Pioneer Hyperformance mini split is Energy Star certified, meaning it meets strict efficiency standards to help reduce energy consumption and lower utility bills.
Q: What size area does this 12,000 BTU unit cover?
A: This system is ideal for spaces up to 500 square feet, making it perfect for bedrooms, offices, or small living areas.
Q: Does it provide both heating and cooling?
A: Yes, this unit functions as both an air conditioner and a heat pump, ensuring year-round comfort by cooling in the summer and heating in the winter.
Q: Is installation easy?
A: The system includes a complete installation kit, but professional installation is recommended to ensure optimal performance and efficiency.
Q: Why choose a ductless mini split over a traditional HVAC system?
A: Ductless mini splits offer higher efficiency, zoned climate control, and easier installation compared to traditional central HVAC systems, making them an excellent choice for energy-conscious homeowners.
Maintenance Tips
-
Clean or Replace Air Filters: Wash or replace filters every 1-3 months to maintain airflow, energy efficiency, and indoor air quality.
-
Inspect and Clean Coils: Keep the evaporator and condenser coils free of dust and debris to optimize heat exchange and prevent performance issues.
-
Clear the Condensate Drain: Ensure the drain line is free from clogs to prevent water leaks and mold buildup. Flush with warm water or use a wet/dry vacuum as needed.
-
Check the Outdoor Unit: Keep the condenser free from obstructions, such as leaves and dirt, to maintain proper airflow and prevent overheating.
-
Monitor Refrigerant Lines: Inspect for leaks or damage and ensure insulation is intact to maximize efficiency.
-
Test Heating and Cooling Performance: Run the system in both modes periodically to ensure proper function and detect potential issues early.
-
Listen for Unusual Noises: Strange sounds may indicate loose parts or refrigerant issues; schedule an inspection if needed.
-
Schedule Annual Professional Maintenance: A technician should check refrigerant levels, clean internal components, and ensure peak performance.